Flameproof enclosures EJC Ex d IIC
Marking
ATEX:
Ex II 2G Ex db IIC T6..T3 Gb
Ex II 2D Ex tb IIIC T80°C..T130°C Db
IECEx:
Ex II 2G Ex db IIC T6..T3 Gb
Ex II 2D Ex tb IIIC T80°C..T130°C Db
Guidelines/Norms
EN-IEC 60079-0,-1
Ambient temperature
-20 °C to +40 °C standard
-40 °C to +55 °C optional
-55 °C to +80 °C maximum for some applications
Description
Flameproof enclosures BARTEC C or EJC series are designed to be installed in industrial plants, where potential hazardous atmos-pheres occur. These areas are either classified as zone 1 and 2 or as zone 21 and 22. These enclosures are designed to contain regular industrial electrical components or equipment on the mounting plate like fuses, transformers, circuit breakers, relays, PLC etc. and to be fully integrated in the hazardous area as control- or distribution panel.
Technical data *
Protection class | max. IP 66 |
Material | Enclosure material: Copper free aluminium alloy (< 0,1% copper) Surface treatment: External painted RAL 9006 (standard) Internal anti-condense painting RAL 2004 (optional) Enclosure lid: Bolts in stainless steel SS304 |