Vapor Pressure Process Analyzer RVP-4

To remain competitive, today’s refiners must employ all optimization and product control techniques available. The use of online physical property analyzers is one of the key features to reach those objectives because they measure important quality properties in the process directly. The vapor pressure is an indication of a liquid evaporation rate and relates to the tendency of volatile components to escape from the liquid. To assure safe storage and transportation of petroleum products, minimize environmental pollution and assure proper functioning of combustion engines it is important to measure the vapor pressure.


Benefits

  • ASTM compliant cylinder piston design with 4:1 expansion
  • Suitable for high pressure applications (LPG)
  • Suitable for high viscous samples (Crude Oil) without flushing cycles
  • No maintenance approach
  • Integral temperature control unit
  • Network and fieldbus communication


Technical Data

Technologyexpansion with piston
4:1 expansion
Methodcompliant: ASTM D5191, DIN EN 13016-1, ASTM D6377 (VPCR4)
fuel up to 1.6 bar (23 psi), LPG up to 16 bar (232 psi)
≤ DIN EN/ASTM, fuel typ. 1.5 mbar (0.02 psi), LPG typ. 50 mbar (0.73 psi)
≤ DIN EN/ASTM
discontinuous, cycle time 7 min typically, depends on sample composition
Sample at inletfiltered 10 μm, moisture content max. 500 ppm, ≤ 200 cSt at inlet temperature
pour point 15 K below measuring temperature or cloud point temperature; for crude oil applications WAT needed
approx. 2 to 10 l/h (depends on product); approx. 30 l/h for re-cooling of peltier device; (not required if suitable coolant is available)
min. 2 bar (29 psi) above measuring range; standard: up to 8 bar (116 psi); optional: up to 18 bar (261 psi)
Standard: TM** 45 °C: TM**-40 K TINLET *** max. 45 °C(113 °F) Optional: TM**> 45 °C: TM**-30 K TINLET *** TM**+5K variation of temperature should not exceed 0.2 K/min
Sample at outletcan handle back pressure (on request)
Electrical datamax. 8 (4 to 20 mA; 1000 Ω); active isolated on request
4 to 20 mA; 160 Ω
24 V DC; max. 0.5 A
high: 15 to 28 V DC/low: 0 to 4 V DC
24 V DC; max. 0.8 A
CommunicationMODBUS/RTU via RS485 or RS422 or FOC is
MODBUS/TCP via FOC is
ethernet available
vapor pressure (others on request)
Alarm, Ready/Valid; Stream Selection, Validation Request, Reset
Ambient conditionsoperation 5 to 40 °C (41 to 104 °F); storage -20 to 60 °C (-4 to 140 °F)
operation 5 to 80 % relative humidity,storage 5 to 80 % relative humidity, – both are non-corrosive
IP 54 (comparable with NEMA 13)
HMItouch display 19"
remote access on request
cyber security
operating system Windows10 enterprise LTSB
Bartec Benke control software PACS
Process connectionstube fittings: typically Swagelok 6mm/12mm/18mm; others on request
sample inlet up to 2 sample streams and 1 validation stream
sample outlet
vent line (if required)
coolant (if required)
Weight and dimensionsapprox. 250 kg
(W x H x D) approx. 1190 x 1930 x 710 mm
free space right: 150 mm/left: 100 mm
Datasheet download